Pacific Power Source AFX Series Operation Manual page 258

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Query Format
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Parameters
Parameter Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
PROGram:EXECuted:MEMory?
This command selects the specific program memory type for storing
and retrieving programs. Default is INTERNAL memory. Alternatives
are RAM and USB devices. The memory type can also be specified as
an optional parameter with several PROGram commands where
indicated in this manual.
Memory types: INTERNAL | RAM | USB
<cr>
PROG:EXEC:MEM USB
PROGram:EXECuted:MEMory?
<cr>
PROG:EXEC:MEM?
USB
PROGram:POWOn <nr1>
Returns the number of the stored program that will be recalled at
power on.
Program number
<nr1>
PROG:POWO 1
PROGram:POWOn?
<nr1>
PROG:POWO?
1
PROGram:DELete:ALL <cr>
This command deletes all programs, waveforms and setup values,
performs device RESET, loads Program #1 with *RST default values,
executes MANUAL MODE with *RST values. Waveforms (1-16) are
re-loaded from internal Flash memory. Attempting to DELete an
EXECuting Program will result in an error message.
Optional: Memory type: INTERNAL | RAM | USB
<cr>
PROG:DEL:ALL USB
PROGram:CATalog? <cr>
This query returns a comma separated list of <nr1> values
representing stored programs (e.g. 1,2,7...). If the MANUAL MODE
program setup exists, the list will include 0. If no programs are stored
at all, this query returns a 1
Optional: Memory type: INTERNAL | RAM | USB
<cr>
<nr1>,<nr1>,....,<nr1>,<nr1>
PROG:CAT?
0,1,2,9,12
PROG:CAT? INTERNAL
0
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 258 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents