The mode can be set from the front panel or by using the following SCPI commands:
Transient start mode:
Output Relay mode:
Program Change mode:
The following specifications apply to the external trigger output:
Output Voltage @ 0.4 mA Logic Low Vout < 0.4 V
Max. Current
Output Impedance
Pulse Width
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
SECTION 7:
SYSTem:DIO:STROBE:TRANsient 0/1
PROGram:TRANsient:TRIGger:OUTput 0/1
SYSTem:DIO:STROBE:OUTPutstate 0/1
SYSTem:DIO:STROBE:SOURce 0/1
Log High Vout > 4.6 V
± 10 mA
100 Ω
190 us ± 10 us
2.0 msec ± 10 µs
Figure 7-7: Transient Trigger Output Pulse
Figure 7-8: Function Strobe Output Pulse
AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
For Transient Trigger mode
For OUTPutstate & SOURce
modes
(alias)