Pacific Power Source AFX Series Operation Manual page 306

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
[SOURce:]STEP:COUNT:MINimum?
This command returns lowest permissible set value for the STEP
count setting.
<nr1>
STEP:COUNT:MIN?
1
[SOURce:]STEP:COUNT:MAXimum?
This command returns highest permissible set value for the STEP
count setting.
<nr1>
STEP:COUNT:MAX?
200
[SOURce:]STEP:COUNT:DEFault?
This command returns default set value for the STEP count setting.
<nr2>
STEP:COUNT:DEF?
10
[SOURce:]STEP:HOLD < 0 | OFF 1 | ON >
This command determines what happens to the source output after
the step transient finishes. If ON, the last step value will be set as the
steady state output when the step execution ends. If OFF, the output
will revert to the original steady state setting in effect before the step
transient execution.
< 0 | OFF | 1 | ON >
<cr>
STEP:HOLD ON
[SOURce:]STEP:HOLD?
<b>
STEP:HOLD?
1
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 306 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents