Pacific Power Source AFX Series Operation Manual page 467

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Error Source
Code
Primary Fault
212
Primary Fault
213
Primary Fault
214
Primary Fault
215
Primary Fault
216
Primary Fault
217
Primary Fault
218
Primary Fault
219
Primary Fault
220
Primary Fault
221
Primary Fault
222
Primary Fault
223
Primary Fault
224
Primary Fault
226
Primary Fault
227
Primary Fault
228
Primary Fault
229
Primary Fault
230
Primary Fault
231
Primary Fault
232
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
Error
AC input: voltage is below
minimum.
Error
AC input: missing phase.
Error
PFC DC bus voltage
regulation lost.
Error
PFC DC bus voltage limit
exceeded. CLA OVP Trip
Error
Temperature 1 protection
(input stage)
Error
Temperature 1 protection
(input stage)
Error
Temperature 2 protection
(PFC/LLC)
Error
Temperature 2 protection
(PFC/LLC)
Error
Temperature 3 protection
(PFC/LLC)
Error
Temperature 3 protection
(PFC/LLC) exceeded
minimum limit.
Error
Temperature 4 protection
(main transformer)
Error
Temperature 4 protection
(main transformer)
Error
Internal bias supply fault.
Error
Hardware does not match
input voltage setting.
Error
Primary capacitor board
not detected.
Error
Invalid node ID. Run unit
discovery to recover.
Error
Incorrect DSP type
detected. Cycle-power to
re-try.
Error
PFC output current peak
protection.
Error
PFC output current slow
protection
Error
AC input: voltage is above
maximum.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
AC Input Stage heatsink
temperature exceeded
maximum limit.
AC Input Stage heatsink
temperature exceeded
maximum limit.
PFC and DC/DC Converter
heatsink temperature
exceeds maximum limit.
PFC and DC/DC Converter
heatsink temperature
exceeds maximum limit.
PFC and DC/DC Converter
heatsink temperature
exceeds maximum limit.
PFC and DC/DC Converter
heatsink temperature
exceeds minimum limit.
High Frequency
Transformer temperature
exceeds maximum limit.
High Frequency
Transformer temperature
exceeds minimum limit.
Internal Bias Supply fault
occurred
Incorrect AC input voltage
detected
An inconsistency was
detected in the power
source's internal
communication network.
An inconsistency was
detected in the power
source's internal
communication network.
Unable to detect correct
DSP type.
PCF stage output current
exceeded maximum peak
level.
Incorrect AC input voltage
detected
Resolution
Check for possible air
flow obstructions and
ambient temperature
Check for possible air
flow obstructions and
ambient temperature
Check for possible air
flow obstructions and
ambient temperature
Check for possible air
flow obstructions and
ambient temperature
Check for possible air
flow obstructions and
ambient temperature
Check for possible air
flow obstructions and
ambient temperature
Check for correct AC
input voltage connection.
Check for correct AC
input voltage rating.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Try cycling AC input
power.
Possible overload on one
or more output inverters.
Check for correct AC
input voltage rating.
Page 467 of 485