Original reading start sensor adjustment

When the RADF board or the original reading start sensor (sensor section or prism) is replaced,
be sure to perform this adjustment. If not, paper jams (E721, E725, E774) or operational
problems may occur.
[A] Automatic adjustment
(1)
Turn the power ON while pressing [0] and [5] simultaneously.
(2)
Key in [3210] and then press the [START] button.
Notes:
Be sure to close all of the RADF cover before the adjustment is performed.
Check that there is no paper on the original reading start sensor so that the light is not
shielded.
[B] Manual adjustment
Notes:
When the reading start sensor is replaced or re-installed, perform this manual adjustment.
(1)
Take off the left RADF cover.
(2)
Close the original jam access cover and the RADF.
(3)
Turn the power ON while pressing [0] and [5] simultaneously.
(4)
Key in [3221] and then press the [START] button.
Notes:
Be sure not to close or open the original jam access cover and the RADF until step 6 is finished.
If you do so, the adjustment value will be reset. In this case, repeat the adjustment from step 2.
(5)
Loosen 2 prism vertical adjustment screws of
the prism.