4.11.32 Original reverse solenoid (SOLR2)
(1)
Take off the RADF rear cover.
 P. 4-258"4.11.3 RADF rear cover"
(2)
Disconnect 1 connector.
(3)
Remove 2 screws and take off the original
reverse solenoid with the bracket.
(4)
Remove 2 screws and take off the bracket
from the original reverse solenoid.
Notes:
Before taking off the solenoid, read the scale.
When reinstalling, align it with the
corresponding position on the scale.