Temperature/Humidity Sensor; Toner Motor Interlock Switch - Toshiba e-STUDIO 5540C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

4.6.51
Temperature/humidity sensor (S12)
(1)
Take off the laser unit cooling duct.
 P. 4-38"4.4.2 Laser optical unit cooling
fan (front) (F22)"
(2)
Remove 1 screw and then take off the

temperature/humidity sensor.

Notes:
Be sure to attach the temperature/humidity
sensor to the MFPs correspondingly since it
differs between e-STUDIO5540C/6540C/
6550C and e-STUDIO5560C/6560C/6570C.
e-STUDIO5540C/6540C/6550C:
The mark on the connector is black.
e-STUDIO5560C/6560C/6570C:
The mark on the connector is red.
4.6.52
Toner motor interlock switch (SW3)
Notes:
When the toner motor interlock switch (SW3) is replaced or removed, be sure to perform the
operation check with the output check (test mode 03). If the installation is insufficient, this switch
is not performing properly. In this case, you may touch the rotating portions such as the gear in
the toner motor during the drive and could be injured as a result.
(1)
Take off the left corner cover.
 P. 4-8"4.1.21 Left corner cover"
(2)
Take off the bridge unit.
 P. 4-213"4.10.11 Bridge unit"
(3)
Insert 2 rails all the way in.
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Temperature/humidity sensor
Fig. 4-394
e-STUDIO5540C/6540C/6550C
Fig. 4-395
Fig. 4-396
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
4 - 135
e-STUDIO5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT