6.7.4
Adjusting the clearance of the paper and side guides
If the clearance between the paper and the side guides is too wide, it can be adjusted to between 0 and
1 mm (the clearance between the paper and the guides is 1 to 2 mm (including both front and rear
sides))
<Procedure>
(1)
Take off the drawer.
(2)
Lift up the paper tray and let it run up onto
the stopper in the front of the drawer. Then
lift it up further to remove it.
(3)
Set the side guide to the 12 inch mark.
(4)
Loosen 2 screws.
(5)
Move the side guide adjustment piece to the
rear and tighten the screws (by 0.5 mm).
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved