Toshiba e-STUDIO 5540C Service Manual page 321

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

(4)
Remove 2 screws and take off the fixing
bracket [1] on the front side.
(5)
Remove 2 screws and take off the fixing
bracket [1] on the rear side.
(6)
Fold the frame with its rear side down.
(7)
Pull out the transfer belt upward to take it off.
Notes:
When replacing the transfer belt, check the
cleanable facing roller, 2nd transfer facing
roller and tension roller, and clean them with
alcohol. If 1st transfer roller has foreign
matter adhering to it, remove this before
installing the transfer belt.
Notes:
1. Install the transfer belt in the middle so
that it will not move to one side.
2. When installing, be sure that the serial
number indicated the inside of the belt is
shown at the front side.
3. Do not touch the belt surface directly with
bare hands.
4. Be sure not to scratch the belt surface.
5. When replacing the transfer belt, clean
the cleanable facing roller, 2nd transfer
facing roller, tension roller and idling roller
with alcohol.
6. Attach a belt guide so that the rib of the
transfer belt will not be run on the
detection roller.
7. After the transfer belt is installed, rotate
the cleanable facing roller in the direction
of the arrow to set the value of the cutting
angle indicator to 0+/-0.5 degree.
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
[ 1 ]
Fig. 4-429
Fig. 4-430
Fig. 4-431
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
4 - 147
[ 1 ]
Serial number
Transfer belt
Cutting angle indicator
-0.5 0 0.5
DISASSEMBLY and REPLACEMENT