Check item
Fuser unit
LGC board
Status counter
Replace parts
Pressure roller thermistor
Fuser unit
Power supply
LGC board
[C471] IH board initialization abnormality
[C472] Power supply abnormality
Classification
Fuser unit related service call
Check item
Power supply
Duplexing unit interlock switch.
Thermostat
Fuser unit
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
Unit check
Connector check
Harness check
Connector check (CN301, CN306)
Harness check
1. [0], [8] Power ON.
2. Key in "2002", then press [START].
3. Change the current status counter value (08-2002) "5",
"6", "8", "18", "20", "26", "28", "33" or "34" to "0"
4. Turn the power OFF and then back ON. Make sure that
the equipment enters the normal ready state.
Remarks:
The status counter value is set as follows in the
following cases.
The error occurred during warming-up: "5" or "6"
The error occurred after the equipment has become
ready: "33"
Regardless of the equipment's status (i.e. during
warming-up or in ready status), when the
temperature detected by the pressure roller
thermistor is 210C or higher: "8", "18", "20", "26" or
"28". The error occurred during printing: "34"
Power is not supplied to the IH board. Or there is trouble in
the power supply environment of the installation location.
Check if the power voltage is normal.(Is the voltage during
the operation ±10% of the rated voltage?)
Connector check
Power cable check
Switch check
Install check
Sensor check
Install check
Unit check
Connector check
Harness check
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
8 - 122
Measures
Remarks
Error item
Measures