Toshiba e-STUDIO 5540C Service Manual page 599

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

(5)
When the adjustment has finished normally, press the [OK] button to have the adjustment results
reflected.
(To cancel the reflection of adjustment results, press the [CANCEL] button.)
In the case of an abnormal ending, "ADJUSTMENT ERROR" is shown. Press the [CANCEL]
button to clear the error display.
When it is cleared, the control panel display will return to the ready state. Then, check if the patch
chart on the original glass is placed in the wrong direction or if it is placed inclined on the original
glass, and then repeat step (3) and afterward.
To select the paper type for the automatic gamma adjustment in user calibration, change the code
below to "1". (copy/print)
Code
08-9059
0: No paper selecting buttons displayed
1: Paper selecting buttons displayed. (For both Copy and Printer)
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Remarks
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
6 - 51
SETTING ADJUSTMENT
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents