9.2.4

Precautions and Procedures when replacing the SYS board

A procedure for SYS board replacement is shown below.
Notes:
"[C] Update system ROM version (Jig)" is required only for the equipment in which the ADI-HDD
has been installed and the OS version is less than "2000".
"[E] Restore ADI key" is required only for the equipment in which the ADI-HDD has been
installed.
[A] Return License
Notes:
If the Setting Mode (08) is not started up, "[A] Return license" can be omitted.
In that case, since "[F] Reinstallation of License" cannot be performed, reinstall the license
with [ 1 ]Re-registration when the board is replaced.
When installing the Data Overwrite Enabler (GP-1070) and security mode is setting High
Security, set the security mode level to "1" (Low level). Then restart the equipment.
(1)
Start up with the Setting Mode (08).
(2)
Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [ENTER] button without entering anything.)
(3)
Key in [3840], and then press the [ENTER] button.
(4)
Select the license to be returned, and then press the [REMOVE] button.
(5)
Install the one-time dongle, which you used for uploading the selected license, in the equipment,
and then press the [OK] button.
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
REPLACEMENT OF PC BOARDS/HDD
START
[A]
[B]
SATA-HDD
[D]
[F]
[G]
[H]
[I]
END
Fig. 9-66
9 - 30
ADI-HDD
[C]
[D]
[E]
SATA-HDD: Normal HDD
ADI-HDD: Securely HDD
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents