[E870] RADF open jam
Classification
RADF jam
Check item
RADF
RADF opening/closing sensor
RADF board
Replace parts
RADF opening/closing sensor
RADF board
[E871] Cover open jam in the read ready status
Classification
RADF jam
Check item
RADF
Original jam access cover opening/
closing sensor
RADF board
Replace parts
Original jam access cover opening/
closing sensor
RADF board
[E890] ADF time out jam
Classification
RADF jam
Check item
RADF
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
RADF has opened during RADF operation.
Close the RADF if it is opened.
Remove if there is any original before closing it.
Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[D])
Connector check
Harness check
Connector check (CN74)
Board check
Perform the 05-3210
Jam caused by opening of the Original jam access cover or
front cover while the RADF is waiting for the scanning start
signal from the equipment.
Close the RADF if it is opened.
Remove if there is any original before closing it.
Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[C])
Connector check
Harness check
Connector check (CN74)
Board check
Perform the 05-3210
ADF time out jam
Check if there is any paper in the RADF. Remove it if there
is.