Cause/Section
Step
High-voltage
14
Is the high-voltage transformer output
transformer
settings improper?
(developer
15
Are the connector of the high-voltage
bias)
harness securely connected? Is the
harness open circuited?
2nd transfer
16
Is there any abnormality on the cam,
contact/release
pusher and actuator?
unit
(cam unit)
17
Is the 2nd transfer pressure reduction
operating correctly during Thick
paper printing?
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Check item
8 - 329
Measures
Adjust the high-voltage transformer
output.
Reconnect the harness securely.
Replace the high-voltage harness.
Check if the cam, pusher and
actuator are installed correctly and
there are no damages on them.
Repair or replace them if needed.
Invalidate the 2nd transfer pressure
reduction operation (change the
value from "1" to "0" for 08-4663.),
and check if the transfer failure is
cleared.
If it still persists, perform step 16
again.