Toshiba e-STUDIO 5540C Service Manual page 927

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

Check item
Image quality sensor (S23)
IMG board
SYS board
HDD
Replace parts
HDD
SYS board
[CE50] Temperature/humidity sensor abnormality
Classification
Image control related service call
Check item
Temperature/humidity sensor (S12)
LGC board
Replace parts
Temperature/humidity sensor
LGC board
[CE60] Drum thermistor-Y abnormality
[CE90] Drum thermistor-K abnormality
Classification
Copy process related service call
Check item
EPU tray (process unit)
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Sensor check
Connector check
Harness check
Connector check (CN422)
Harness check
Connector check (CN116, CN132, CN135)
Harness check
Format the HDD. ([5] + [C] + [POWER] ON -> [3] -> [2])
Connector check
Harness check
The output value of this sensor is out of a specified range.
Sensor check
(Perform the input check: 03-[ALL]OFF/[1], 03-[ALL]OFF/
[2])
Connector check
Harness check
Connector check (CN310)
Harness check
The output value of the drum thermistor-Y is out of a specified
range. (CE60)
The output value of the drum thermistor-K is out of a specified
range. (CE90)
Connection check (05-2788)
Connector check(CN551, CN553, CN556)
Harness check
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
8 - 171
Measures
Remarks
Error item
Measures
Remarks
Error item
Measures
ERROR CODE and TROUBLESHOOTING