(4)
Insert the gauge "0.60" of the doctor-sleeve
jig into the gap between the developer
sleeve and the doctor blade and make sure
that the gauge can move smoothly in the
front/rear direction. In addition, confirm that
the gauge "0.70" cannot be inserted into the
gap.
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
0.60 mm
Doctor blade
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
6 - 94
Doctor-sleeve gap jig
0.70 mm
Fig.6-55