Adjustment Of Auto-Toner Sensor - Toshiba e-STUDIO2006 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

6.2

Adjustment of Auto-Toner Sensor

When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-2000))
(1)
Install the developer unit into the equipment.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
(3)
Key in code [2000] and press the [START] button.
The display changes as follows.
[2000]
Notes:
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
(4)
After about two minutes, the value B automatically starts changing.
Notes:
A indicates the controlled value of the auto-toner sensor output. Press the Up or Down button to
change the value.
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
SETTING / ADJUSTMENT
TEST MODE A
MC=
[0][5]
[POWER]
Fig.6-2
TEST MODE A
MC=2000
230
[START]
Fig.6-3
TEST MODE A
MC=2000
245 128
Fig.6-4
6 - 2
B
WAIT
B
A