Notes:
1. When the wire holder jig is attached,
make sure that the wire is not shifted or
loosened.
2. The wire should come out of the slot of
the wire holder jig and be passed under
the arm of it.
(3)
Detach the tension springs of the front and
rear sides.
(4)
Remove the carriage wires.
(5)
Rotate the carriage-2 in the direction where
the inside of the frame is dented shown in
the figure at right, not to touch the mirrors.
Then take off the carriage-2.
Notes:
1. When replacing the mirrors-2 and -3,
replace the carriage-2 together with
mirrors-2 and -3. Mirrors-2 and -3 should
not be removed.
2. When installing carriage-2, fix the front
bracket temporarily and move it in the
direction of (B) after the wires are
installed. Then push it to the end and fix it
securely.
( P. 4-29"Fig. 4-81 ")
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Wire holder jig
Wire holder jig
Fig. 4-85
Tension spring
Fig. 4-86
Fig. 4-87
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
4 - 31
Arm
Tension spring
( B )
DISASSEMBLY and REPLACEMENT