(5)
Take off the bridge unit transport roller-2 by
removing 2 E-rings and a bearing.

4.10.19 Bridge unit transport roller-3

(1)
Take off the reverse roller.
 P. 4-225"4.10.20 Reverse roller"
(2)
Take off transport guide-2.
 P. 4-229"4.10.25 Bridge unit path
entrance sensor (S55)"
(3)
Take off bridge unit exit roller-1.
 P. 4-225"4.10.21 Bridge unit exit roller-1"
(4)
Take off the transport guide unit by removing
2 screws and disconnecting the connector.
(5)
Remove the spring and 2 screws. Then
remove the actuator.