6.7.3

Automatic original detection sensor (APS sensor)

[C-1] A4 series (S9-S13)
(1)
Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2)
Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 5 APS
sensors.
Note:
When installing the automatic original
detection sensor, connect the connector
(yellow) to the connect one.
[C-2] LT series (S10-S13)
(1)
Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2)
Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 4 APS
sensors.
Note:
When installing the automatic original
detection sensor, connect the connector
(yellow) to the connect one.
6.7.4

Scan motor (M1)

(1)
Take off the scanner top cover.
P.6-17 "6.7.2 Scanner top cover"
(2)
Disconnect 1 connector.
e-STUDIO182/212/242
SCANNER
Connector (Yellow)
Connector (Yellow)
© 2009 TOSHIBA TEC CORPORATION All rights reserved
6 - 18
Sensor
Connector
Fig. 6-16
Sensor
Connector
Fig. 6-17
Connector
Fig. 6-18