4.7.23
TRU waste toner motor (M10)
(1)
Take off the 2nd transfer unit.
 P. 4-154"4.7.14 2nd transfer unit (TRU)"
(2)
Disconnect 1 connector [1] and remove 1
screw. Then take off the bracket [2].
(3)
Remove 2 screws and then take off the TRU
waste toner motor.
Notes:
Pay attention to the size (length) of the
screws. If incorrect ones are used, the motor
could be damaged.
4.7.24
Transfer belt motor (M13)
(1)
Take off the transfer belt unit.
 P. 4-144"4.7.6 Transfer belt unit (TBU)"
(2)
Remove 1 screw, and take off the harness
cover [1].
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
[ 1 ]
[ 1 ]
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
4 - 162
[ 2 ]
Fig. 4-474

TRU waste toner motor

Screw
Fig. 4-475
Fig. 4-476