4.3.4
Automatic original detection sensor <APS sensor> (S1-5)
[A] A4 series (APS-1, -2, -3, -C, -R)
(1)
Take off the original glass.
 P. 4-15"4.3.1 Original glass"
(2)
Take off the lens cover.
 P. 4-16"4.3.2 Lens cover"
(3)
Disconnect 1 connector, remove 1 screw and
take off the APS sensor.
(4)
Disconnect 1 connector each, release 2
latches each and take off 4 APS sensors.
[B] LT series (APS-2, -3, -C, -R)
(1)
Take off the original glass.
 P. 4-15"4.3.1 Original glass"
(2)
Take off the lens cover.
 P. 4-16"4.3.2 Lens cover"
(3)
Disconnect 1 connector, remove 1 screw and
take off the APS sensor.