6.9
Transfer Unit
6.9.1

Adjustment of the degree of the transfer belt unit parallelization

By default, the position of the transfer belt unit has been adjusted using the lever assembly bracket in
order to regulate the parallelization between the unit and the registration roller.
Therefore, when the transfer belt unit or the lever assembly has been replaced, make sure it is aligned
with the position before the replacement.
<Checking method>
Check the position of the lever assembly bracket of the transfer belt unit currently installed
The bracket can be assembled in the following three positions
1. Normal position
2. Pushed to the upper end (Rotate the bracket a half turn.
3. Pushed to the lower end (Rotate the bracket a half turn.)
Adjustment is not needed when the bracket position of the new unit or assembly is the same as that
of the unit before the replacement.
When the bracket position of the new unit or assembly is the same as that of the new one, align the
bracket to the installation position before the replacement.
<Changing procedure of the bracket position>
When the cut-out portion of the bracket before the replacement is facing downward
Remove 2 screws from the transfer belt unit to be replaced and rotate the bracket a half turn
Align the bracket in the position the same as that before the replacement (pushed to the upper/lower
end) and fix it with 2 screws.
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Normal
Bracket
Upper
Fig.6-56
6 - 95
Half turn
Lower
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C