(13) Rotate the releasing cam so that the
pressure roller and the fuser belt do not
contact, and then take off the pressure roller
frame unit.
Notes:
When installing, rotate the cam as shown in
the figure and then install the pressure roller
frame unit.
(14) Remove the C-ring and the gear from both
sides of the pressure roller.
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Pressure roller frame unit
Fig. 4-522
Fig. 4-523
C-ring
Fig. 4-524
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
4 - 181
C-ring
Gear