Carriage-1 - Toshiba e-STUDIO 5540C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

(4)
Release the harness from the harness
clamp.
(5)
Remove 3 screws and take off the scan
motor with the whole bracket.
Notes:
When installing the scan motor, be sure to
perform the belt tension adjustment.
 P. 6-82"6.6.2 Belt tension adjustment of
the Scan motor"
4.3.13

Carriage-1

(1)
Take off the original glass.
 P. 4-15"4.3.1 Original glass"
(2)
Take off the top rear cover.
 P. 4-7"4.1.20 Top rear cover"
(3)
Take off the top front cover.
 P. 4-2"4.1.5 Top front cover"
(4)
Move the carriage and position the holes of
the carriage to the holes of the frame.
(5)
Remove 2 screws and take off the brackets
fixing the carriage-1 to the wire.
(6)
Remove the square seal fixing the lamp
harness to the base. Disconnect the
connector of the lamp harness from the SLG
board
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
Screw
Connector
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
4 - 28
Scan motor
Fig. 4-75
Fig. 4-76
Seal
Fig. 4-77