AIR CONDITIONING
-
Service
Adjustment
Procedures
SERVICE ADJUSTMENT
PROCEDURES
N24FDAA
MANIFOLD
GAUGE SET INSTALLATION
Suction gauge
Discharge
gauge
Discharge
port
I
Suction port
2OY1630
Manifold
Gauge
Valves
- should be closed when
connectrng
the manifold
gauge
set to the servrce port of the compressor
and the drscharge
line% The suction
gauge
valve at the left is ;
opened
to provrde a passagebetween
the suctron
gauge
and
the center
manrfold
outlet.
The discharge
gauge
valve at the .-
right IS opened
to provide
a passage
between
the discharge
__
pressure
gauge :and the center
manifold
outlet.
Detailed
rnstructCons
for proper
use of the gauge
set manifold
z
dre contained
in the
text covenng
each
test
and
service
operation
employrng
these
gauges.
_z
Suction
Gauge
- the lett side of the manitold~set
is calibrated
to register
0 to -100
kPa (0 to 30 in. of vacuum)
and 0 to 1,000
'I
kPa (0 to 150 psj). This gauge
IS
connected
to the suction
port
of the compressor.
-
Discharged
Gauge
- the rrght of the manifold
set IS calibrated
to regrster 0 to 2,100 kPa (0 to 300 psi). For all tests this gauge
;
IS connected
to the discharge
port of the system
Center
Manifold
Outlet
- provides
the necessary
connection
for a long service
hose
used when
discharging
the system,
using a vacuum
pump to "pull a vacuum"
before
charging
the __
system,
and for connecting
the supply
of refrigerant
when
chargrng
the system.