JVL MIS17 Series User Manual page 95

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

5.2
5.2.3
Setup with MacTalk
Following parameters are available in MacTalk.
In position window
Defines the window wherein the motor must be before the In Physical Position flag is set.
Autocorrection velocity
Defines the velocity used if a correction is done. Can be useful when Ethernet or other
protocol is used since the main velocity register can be overwritten with a velocity value
which is not optimal for auto correction.
Max number of retries
Defines how many auto correction retries that are allowed to be done
Settling time between retries
Defines defines the time between the auto correction retries
Update the In Physical Position bit continuously
Defines if the In Physical Position bit is updated continuously or only after the motor has
stopped (default)
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Auto Correction
Only MISxxx---H2/H3/H4---
95

Hide quick links: