JVL MIS17 Series User Manual page 194

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

8.2
8.2.12
V_START
Reg
Name
13
V_START
Description: The start velocity. The motor will start the acceleration at this velocity. It will also stop
the deceleration at this velocity. If |V_SOLL| is lower that V_START the motor will not
accelerate at all, but start to run at V_SOLL instantly. The motor will actually start the
movement with an internal V_START = V_SOLL.
If V_START is changed during a movement, it will first be active when the motor stops
or changes direction. This also means that if V_SOLL is changed to a value below
V_START, while the motor is in motion, the motor will decelerate to V_START
and run at that velocity.
Example:
V_START = 10000 (100 RPM), V_SOLL = 20000 (200 RPM), MODE_REG = 1. The
motor will accelerate from 100 RPM to 200 RPM.
V_SOLL is now changed to 5000 (50RPM). The motor will decelerate to 100 RPM and
continue at 100 RPM.
V_SOLL is now changed to -50 RPM. The motor will stop and start at -50 RPM.
8.2.13
GEAR1
Reg
Name
14
GEAR1
Description: When the gear mode is active, the input from the external encoder is multiplied by
GEAR1 and divided by GEAR2.
Example:
1. GEAR1 = 409600, GEAR2 = 2048. If 2048 counts are applied to the input, the motor
will turn 1 revolution.
2. If one step is applied, the motor will move 200 counts.
8.2.14
GEAR2
Reg
Name
15
GEAR2
Description: The denominator of the gear factor. See GEAR1 for details.
8.2.15
Encoder_Pos
Reg
Name
16
ENCODER_POS
Description: If the internal encoder option is installed, this register shows the position feedback from
the encoder. This value is initialized to zero at power-up and modified by the firmware
when a zero search is performed. The value can be used internally by the AutoCorrec-
tion system to retry a movement in position and gear modes.
194
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
±1-300000
32bit
R/W
(0.01-3000RPM)
Size
Access
Range
32bit
R/W
(-2
Size
Access
Range
32bit
R/W
(-2
Size
Access
Range
32bit
R/W
(-2
Default
10000
(100 RPM)
Default
31
31
409600
)-(2
-1)
Default
31
31
2048
)-(2
-1)
Default
31
31
-
)-(2
-1)
Unit
MacTalk name
RPM/100
Start Velocity
Unit
MacTalk name
Counts
Output
Unit
MacTalk name
Counts
Input
Unit
MacTalk name
Steps
Encoder position

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents