8.2
Reg Name
Size Access Range
151
MOTORTYPE
32bit R
152
SERIAL‐NUMBER
32bit R
154
CHECKSUM_1
32bit R
155
CHECKSUM_2
32bit R
156
HARDWARE_REV
32bit R
157
MAX_VOLTAGE
32bit R
MAX_CURRENT
158
AVAIBLE_IO
32bit R
159
BOOTLOADER_VER 32bit R
160
NOTSAVED
32bit R/W
165
OPTIONS_
32bit R
BITS
166
FBUS_NODEID
32bit R/W
167
FBUS_BAUD
32bit R/W
168
ModuleType
32bit R
170
EXT_
32bit R/W
ENCODER
171
Reserved
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Default Unit
80‐254
0‐65535
0‐65353
0‐65535
Major*16 + 
Minor 
0‐100 
*
Volt
[VDC]
0‐9000 
[mARMS]
IO Mask and 
max current 
from 1‐1532.
0‐65535
Major*16 + 
Minor 
0‐65535
0
0‐65535
1‐127
5
Node id
0‐8
2
0
0
31
31
Counts
(‐2
)‐(2
1)
Description
The motor type.
Examples:
80: SMC85, 81: MIS340, 82: MIS341, 83: MIS342
120: MIS17, 150: SMC66, 151: MIS230, 152: MIS231
250: MIL340
The serial number of the motor.
Firmware checksum part 1
Firmware checksum part 2
The revision of the hardware
Bit 0‐15: Max voltage on bus If the bus voltage 
exceeds this value, the motor will go in 
error.
Bit 16‐31: Full scale motor current in mARMS
Bit 0‐15: Defines what IO that are available on the 
connector – programmed during 
manufacturing.
Bit 16‐31: The max current to the motor.
The version of the boot loader
This register is not used internally, but will always be 
0 after power‐on. Please notice that MacTalk uses 
this register.
This register contains information about what 
options that are available. Bit 0‐7 defines the options 
available in the hardware (or licensed). Bit 8‐15 
defines the options available in the firmware.
Bit 0,8 : CANopen fieldbus
The node id on the CANopen fieldbus interface.
The baudrate used on the CANopen fieldbus 
interface.
0 : 1000 kbit/s
2 : 500 kbit/s
3 : 250 kbit/s
4 : 125 kbit/s
5 : 100 kbit/s
6 : 50 kbit/s
7 : 20 kbit/s
8 : 10 kbit/s
Tells which type of module is connected to the 
internal 1Mbit/s Modbus channel. 
0 = No module
0x34 = EthernetIP
0x35 = EtherCAT 
0x36 = PowerLink
0x37 = Profinet
0x38 = Modbus/TCP
This register counts the external encoder.
(intended for 64‐bit EXT_ENCODER hi‐word)
MacTalk 
name
"Status bar"
"Status bar"
"Tooltip on 
motor"
"Tooltip on 
motor"
"Tooltip on 
motor"
"Tooltip on 
motor"
N/A
"Tooltip on 
motor"
N/A
"Tooltip on 
motor"
CANopen ‐> 
Node Id
CANopen ‐> 
Baud rate
Dedicated 
tab
External 
encoder
185

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents