JVL MIS17 Series User Manual page 214

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

8.2
8.2.69
Turntable_Mode
Reg
Name
TURNTABLE_
126
MODE
Description: In turntable mode, the motor controls the revolution of a turntable that has the number
of positions specified in register 127, Turntable_Size.
This means the same position will be reached after rotating this number of steps in either
direction.
This register selects one of three modes that define how the motor should move to a
new position when the P_SOLL register is changed.
If the value of this register is zero, the motor will not operate in turntable mode.
Several modes of operation exist. Please also see
description.
8.2.70
Turntable_Size
Reg
Name
TURNTABLE_
127
SIZE
Description: If turn table mode is selected in register 126, the number of steps needed for a full rev-
olution of the turn table is set in this register. Note that the register P_SOLL must always
have a value between zero and the value in this register minus one. Negative values are
not allowed for P_SOLL or Turntable_Size.
Please also see
8.2.71
NL_Mask
Reg
Name
129
NL_MASK
Description: Selects which one of the eight IO pins to use for the dedicated function of Negative Po-
sition Limit.
Exactly one bit must be set, and the IO pin must be configured in register 125 as an
input.
Example:
If input 7 is to be used for the Negative Input Limit, write 26 = 64 to this
register.
214
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
32bit
R/W
0 - 6
Size
Access
Range
32bit
R/W
-
Turn Table
Mode, page 139 for detailed description.
Size
Access
Range
32bit
R/W
-
Default
Unit
0
Special
Turn Table
Mode, page 139 for detailed
Default
Unit
0
Steps
Default
Unit
0
IO Mask
MacTalk name
Turn Table Mode
MacTalk name
Turn Table - Size
MacTalk name
Dedicated Inputs
Negative Limit Input