JVL MIS17 Series User Manual page 38

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

2.8
CN2
RS485 IN/OUT
PWR (CN1)
Power input
2.8.2
MISxxxxxxQ5xxxx connector description.
The MIS motors offers robust M12 connectors which makes it ideal for automation ap-
plications. The M12 connectors offer solid mechanical protection and are easy operate.
Following scheme gives the relevant information about each connector and the pins, wire
colours and a short description of the signals available.
The connector layout:
"PWR" (CN1) - Power input. M12 - 5pin male connector
Signal name
P+
P+
P-
CVI
P-
* Note: P+ and P- are each available at 2 terminals. Make sure that both terminals are connected in order
to split the supply current in 2 terminals and thereby avoid an overload of the connector.
(Continued next page)
38
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
How to connect a MIS motor
Description
Main supply +7-72VDC. Connect with pin 2 *
Main supply +7-72VDC. Connect with pin 1 *
Main supply ground. Connect with pin 5 *
Control and user output supply +7-28VDC.
DO NOT connect >30V to this terminal!
Main supply ground. Connect with pin 3 *
TT2332-01GB.cdr
Pin no.
1
2
3
4
5
CN3
RS485 + I/O
CN4
RS485 + I/O + Backup(optional)
JVL Cable
WI1000-
Isolation
M12F5TxxN
group
Brown
1
White
1
Blue
1
Black
1
Grey
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents