4.1
4.1.2
Toolbar description
The toolbar at the top of MacTalk contains the most commonly used features.
Open
Opens a setup file from PC and downloads the setup to the motor. If no motor is con-
nected, the setup is shown in MacTalk and can be edited and saved to the PC.
Save
Saves the actual setup from the motor to a file. If no motor is connected, the actual off-
line settings (including module setups and program) are saved.
Save in motor
The complete actual setup in the basic motor will be saved permanently in the flash
memory. If the motor is powered down or reset, the saved setup will be used.
Reset position
Resets the position counter to 0. The content of the position counter can be monitored
in the right side of the main screen as "Actual position".
Clear errors
Clears all the errors (if any). Please note that if an error is still present, the motor will
remain in the actual error state.
Reset motor
Reset the motor. Same as performing a power off / on operation.
Filter Setup
For specifying the filter setup of the analogue inputs.
STOP motor
Stops the motor immediately using a controlled deceleration ramp and puts the motor
into passive mode. If a program is present this is stopped as well.
This button shall be considered a functional stop button and is available using the
keyboard shortcut F8.
Pressing the "Stop" button will immediately stop the motor by changing the currently
running mode to "passive" using a fast controlled deceleration curve.
Using a quickstep motor or a module that enables the user to execute RxP programs this
execution is also halted to prevent the motor from starting up if a startup-mode is setup
from a program.
Warning! Do not consider this button as an appropriate Emergency stop. Al-
ways fit an Emergency stop circuitry to your motor setup.
Auto Scan
If the actual COM port is not known or the motor is setup with an address different from
default the Auto Scan feature can help finding the motor(s). Auto Scan is also available
when connecting with one of the Ethernet protocols (optional)
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Using the MacTalk software
79