2.1
2.1.4
Power Supply Grounding and Earthing
It is mandatory that the motor flange is connected to earth. Also it is mandatory that the
earth is connected to GND/Common at a central point near the power supply.
The P- (GND/Common) is internally connected to the motor chassis/housing. Also the
outside body at all M12 connectors is connected to the chassis/housing and thereby to
the P- (GND/Common).
The illustration below shows how to make a good power and earth connection of the
MIS motor.
14
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x