9.7
Graphic programming command reference
9.7.15
Wait for an input combination before continuing (multiple inputs)
Icon:
Dialogue:
Function:
Waits for a specified input condition to occur. The next line in the program will
not be executed until the input condition has been met.
If 'Input type' is set to 'Multiple', multiple inputs can be tested for being either
high or low. The 'Operand' setting determines whether one or all of the inputs
must meet their test criterion. If set to 'And', all inputs must match their test
settings. If set to 'Or', only one input need match its test setting. Inputs that
are set to 'Don't care' are not tested. The inputs are tested with 30
microsecond intervals.
254