3.4
3.4.16
STO Technical Data
NOTICE : The STO signal must be SELV or PELV supplied.
European directives
Safety standards
Safety function
Safety performance
Reaction time
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Commissioning
Machinery Directive (2006/42/EC)
EMC Directive (2014/30/EU)
Low Voltage Directive (2014/35/EU)
Safety of Machinery
Functional Safety
ISO 13849-1
Category
Diagnostic Coverage
Mean Time to Dangerous Failure
(per channel)
PFHd
Performance Level
IEC 61508 / IEC 62061 / IEC61800-5-2
Safety Integrity Level
Systematic capability
(systematic integrity level)
Probability of Dangerous Failure
per Hour
Diagnostic Coverage
Safe Failure Fraction
Common Cause Failure Factor
Hardware Fault Tolerance
Proof Test Interval T1
Mission time TM
Input to output response time
Response time (internal fault)
EN ISO 13849-1/2
EN IEC 62061
EN IEC 61800-5-2
EN 61000-6-3
EN 61800-3
EN 61800-5-1
EN ISO 13849-1/2, IEC 62061,
IEC 60204-1
IEC 61508-1/2, IEC 61800-5-2
IEC 61800-5-2
IEC 60204-1
Safe Torque Off
Stop
(STO)
Category 0
Cat 3
DCavg: 98,5 % (Medium)
MTTFd: 100 years (High)
4,29e-8/h
PLe
SIL 3, SIL CL3
SIL 3
PFHd: 1,38e-10/h
(High Demand Mode)
DC: 96 %
SFF: 96 %
CCF 5 %
HFT: 1 (1oo2)
20 Years
20 Years
Maximum 8 ms.
Maximum 200 ms.
Option