3.3
3.3.1
Safety instructions
CAUTION - ELECTRICAL HAZARD
The operator or electrical installer is responsible for proper grounding and compliance
with all applicable national and local safety regulations. Please see
ing and
3.3.2
STO installation
Installation must be in accordance with the following steps and must be carried out by
competent personnel, see
intended to be part of the safety related control system. Before installation, perform a
risk assessment that compares the Safe Torque Off option specifications and all foresee-
able operational and environmental characteristics of the control system. A safety analy-
sis of the machine section controlled by the drive is required to determine how often to
test the safety function for proper operation during the life of the machine.
3.3.3
Enabling the STO function
NOTE: The MIS motors must be ordered with the STO option installed.
The STO option is enabled when the NON-STO plug is not inserted, please see
bling the STO
3.3.4
Cables and connectors
The STO connector contains the two enable inputs STOA and STOB. Both inputs must
be applied nominal +24VDC in order to energize the motor and make any motor move-
ment possible. STO-signals must originate from a safety isolating transformer in accord-
ance with IEC 61558-1 and IEC 61558-2-6 or from a switch mode power supply with
equivalent property. If only one of the inputs is not applied +24VDC the internal STO
circuit will remove the energy from the motor. The illustration below shows the pinout
of the connector. A 100 mA fuse must be inserted in each channel.
Use only the standard cable for the STO function: JVL stock no. WI1010-M08M4V05P.
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x

Installation

Earthing, page
14.
Qualified
function, page 71 to learn more about the NON-STO plug.
personnel, page 60. The Safe Torque Off option is
Option
Power Supply Ground-
Disa-
63