5.12
5.12.2
Configuration via MacTalk.
When using MacTalk for configuration the following parameters are used:
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Turn Table Mode
After the setup is done please remember to save it
in the permanent memory by pressing the
The desired Turn Table Mode
is selected here at the
Advanced
tab
The working range can be defined here
after selecting the type of turn table
mode.
Minimum is the lowest position possible
to reach and maximum is the highest position
that can be reached. Both in encoder counts.
Both values are refering to the zero
position found during the optional zero search
or alternatively the zero point defined if using
an absolute multiturn encoder.
Save in motor
button.
TT2563-01GB