8.2
8.2.48
Encoder_Typ
Reg
Name
99
ENCODER_TYPE
Description: This register monitor which encoder option that is installed in the motor.
0 = No encoder
1 = Absolute single turn encoder 10 bit (H2)
2 = Absolute multi turn encoder (H3)
3 = Absolute single turn encoder 12 bit (H2)
4 = Absolute single turn + multi turn encoder (H4)
8.2.49
Afzup_WriteBits
Reg
Name
100
AFZUP_WriteBits
Description: When changing values for the analogue input filter parameters, this register is used in
combination with registers 102-106. First, all of the registers 102-106 must be loaded
with the values to be used for one or more analogue input filters. Then the lower eight
bits in this register are set to select which inputs the parameters in registers 102-106
should control.
The firmware will detect this and copy the parameter values from registers 102-106 to
internal storage. Once this has been completed, the firmware sets bit 15 in this regis-
ter to show that registers 102-106 are free to receive new values for programming the
remaining inputs with other filter parameters. To use the same filtering for all
analogue inputs, this register can be loaded with 255 (hex FF).
8.2.50
Afzup_ReadIndex
Reg
Name
101
AFZUP_Read Index
Description: This register makes it possible to read back the analogue input filter parameters for one
analogue input at a time. To select a new input, write a value of 1 to 8 to this register and
wait for bit 15 to be set high. When bit 15 has been set by the firmware, the registers
102-106 have been loaded with the filter parameters currently used by that analogue in-
put.
8.2.51
Afzup_ConfMin
Reg
Name
102
AFZUP Conf Min
Description: The minimum confidence limits for analogue inputs are set and read back using this reg-
ister in combination with the read and write 'command' registers 100 and 101.
If a new raw sample value is less than the value in this register, it is simply discarded and
the filtered input value in registers 81-88 will not change. A value of zero in this register
will effectively disable the minimum confidence check.
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
32bit
R
0-10
Size
Access
Range
32bit
R/W
-
Size
Access
Range
0, 1-8,
32bit
R/W
32768-
32775
Size
Access
Range
32bit
R/W
0-4094
Default
Unit
-
-
Default
Unit
0
Special
Default
Unit
0
Special
Default
Unit
0
1.221 mV
MacTalk name
"Tooltip on motor"
MacTalk name
N/A handled on the
Filter Setup screen
MacTalk name
N/A handled on the
Filter Setup screen
MacTalk name
Confidence Min