5.3
5.3.7
Special settings
!
Please note: The following parameters are optional and it is not recommended to mod-
ify them since they are optimized from factory.
The following 2 registers are relevant for the closed loop operation
Motor commutation and encoder setup:
1. KPHASE - register that offsets the magnetic field as function of the velocity
See also: Internal_Encoder_Setup, page 225
2. Internal_Encoder_Setup - register that define the encoder resolution and other en-
coder related parameters. See also: Internal_Encoder_Setup, page 225
Current control advanced registers:
None of the below shown registers are accessible from MacTalk but only from other
protocols such as Ethernet, Modbus, CANopen etc.
The registers shown below are all related to optimizing the current control performance.
R212
R213
R215
R218
R219
Continued next page.
106
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Closed loop operation
CUR_SCALE_MAX
CUR_SCALE_MIN
CUR_SCALE_FACTOR
CUR_SCALE_INC
CUR_SCALE_DEC
The maximum allowable current. 2047 = 100% (of
Running current).
See also: CUR_SCALE_MAX, page 227
!! - its recommended not to use this parameter. Bet-
ter change the "Running current"
The minimum allowable current. 1 = 0,05% (of
Running current).
See also: CUR_SCALE_MIN, page 227
The slope of the velocity dependent current decre-
ment rate.
See also: CUR_SCALE_FACTOR, page 228
Current increment rate (independent of velocity).
See also: CUR_SCALE_INC, page 229
Current decrement rate (at 0 RPM)
See also: CUR_SCALE_DEC, page 229
Only MISxxx---H2/H4---