JVL MIS17 Series User Manual page 151

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

6.4
6.4.3
How to connect the pulse source.
The present firmware require that the external pulse source is applied to specific inputs.
These inputs differ from motor family to motor family.
Other input options are under development.
The external source must be connected to the following inputs:
Quadrature format
Channel A
Channel B
!
6.4.4
Single ended signals
If the external encoder signals are only available as single ended and with voltage levels
up to CVO (typical 24V) it is possible to use IO2+3 as inputs.
To make this change, a small RxP program is required in addition to the settings in
formats
Continued next page
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Gear Mode
I/O terminal
A1+ and A1-
B1+ and B1-
Notice that the Multifunction port pins mentioned above only operate at 5V lev-
els and it is destructive if voltages outside the voltage range 0 to 5V is applied.
supported., page 150 Signal formats supported:
Pulse/direction format
Pulse
Direction
I/O terminal
A1+ and A1-
B1+ and B1-
Signal
G0392-10DK
151

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents