User Inputs - JVL MIS17 Series User Manual

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

2.2
2.2.1

User Inputs

The MIS motors has 8 inputs/outputs (IO's) that each can be set individually to input, out-
put or analogue input 0-5VDC via MacTalk or software commands.
This makes it for example possible to have 4 inputs, 3 outputs and one analogue input.
!
Input/output functional diagram:
2.2.2
General Input features
• Inputs are TTL to 28VDC compliant. Trigger levels LTL=1.2 V and UTL 2.8 V.
• Over-current protection and thermal shut-down.
• 10 kOhm input resistance.
• No galvanic isolation but very robust against noise and spikes/surges.
• Zero search input can be selected to any input 1 to 8.
• Digital filter can be enabled for each input selectable from 0 to 100ms. If disabled (de-
fault), the response time is 100μs.
• Limit switch inputs
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
User Inputs
Please notice: The number of available I/O terminals available may differ de-
pending at which motor type and connector configuration you are using.
Please consult the chapter
Connector overview for the MIS
motors, page 37