JVL MIS17 Series User Manual page 193

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

8.2
8.2.8
Standby_Time
Reg
Name
8
STANDBY_TIME
Description: This register sets the standby time. This time is the time from the last step has been
performed until the current changes from running to standby. When a new request for
a move is received the current changes from standby to running with no delay.
Example:
STANDBY_TIME = 200, will result in the controller switching to the standby current
after 200ms.
8.2.9
Standby_Current
Reg
Name
STANDBY_
9
CURRENT
Description: The current range is defined similar to the running current.
Please see Run_Current, page 192.
The standby current is active when the motor has stopped and the specified Standby
time has elapsed. See Standby_Time, page 193. When the
STANDBY_CURRENT is changed, the new standby current be set instantly.
Example:
STANDBY_CURRENT = 50, will set the standby current to 0.285 ARMS.
8.2.10
P_IST
Reg
Name
10
P_IST
Description: This register shows the actual position of the motor. This is updated each time the motor
makes a step. If P_IST is changed when in position mode or gear mode, the motor
will move until P_IST = P_SOLL. When P_IST reaches 2
Example:
P_IST = 1000, P_SOLL = 1000. P_IST is set to 500. The motor will move 500 steps for-
ward and P_IST will again be 1000.
8.2.11
V_IST
Reg
Name
12
V_IST
Description: This register shows the actual velocity of the motor. The velocity is positive when run-
ning in a positive direction and negative when running in a negative direction.
Example:
If V_SOLL = 40000 (400 RPM) and a movement of -10000 steps is done, V_IST will be
-40000 (400 RPM) during the move and when the move is complete V_IST will be 0.
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
32bit
R/W
1-65535
Size
Access
Range
32bit
R/W
0-1533
Size
Access
Range
32bit
R/W
(-2
Size
Access
Range
±1-300000
32bit
R
(0.01-3000RPM)
Default
500
Default
128
Default
31
31
-
)-(2
-1)
31
Default
-
Unit
MacTalk name
ms
Standby Time
Unit
MacTalk name
5.87 mA
Standby Current
Unit
MacTalk name
Counts
Actual Position
-1, it will wrap around to -2
Unit
MacTalk name
RPM/100
Actual Velocity
31
.
193