8.2
Reg Name
Size Access Range
244
TEMP_LIMITS
32bit R
245
CL_CATCH_UP
32bit R/W
246
TEMP_HIGHRES
32bit R
252
LOWBUSCVI_CNT
32bit R/W
253
V_ENCODER
32bit R
188
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Default Unit
0
Special
0
Special
°C/
1000
10
Counts
‐300,000‐
0.01 
300,000
RPM
Description
The actual temperature limits in the motor:
Bit 0‐15: Warning limit (unit: degC)
Bit 16‐31: Error limit (unit: °C)
Bit 0‐7: Allowable overspeed in percent (0‐100)
Bit 8‐31: Follow error limit before overspeed is used.
Like register 26 but the measured temperature is in 
full resolution and presented in degree celcius x 
1000.
Number of times in a row the voltage can be too low 
before error is set. Time between each 
measurement = 100 us.
The actual internal encoder velocity.
MacTalk 
name
N/A
Allowable 
overspeed
Follow error 
before overspeed
Temperature
N/A
Internal encoder 
velocity