JVL MIS17 Series User Manual page 208

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

8.2
8.2.52
Afzup_ConfMax
Reg
Name
103
AFZUP_Conf Max
Description: The maximum confidence limits for analogue inputs are set and read back using this reg-
ister in combination with the read and write 'command' registers 100 and 101.
If a new raw sample value is larger than the value in this register, it is simply discarded and
the filtered input value in registers 81-88 will not change. A value of 4095 in this register
will effectively disable the maximum confidence check.
8.2.53
Afzup_MaxSlope
Reg
Name
104
AFZUP_ Max Slope
Description: The maximum slopes per sample for analogue inputs are set and read back using this
register in combination with the read and write 'command' registers 100 and 101.
If a new raw sample value on an analogue input lies farther from the previous filtered val-
ue in registers 81-88, the new sample will be modified to lie at most MaxSlope units from
the filtered value. This is used to suppress noise and limit acceleration. Note that the
value is optionally filtered after being slope limited, in which case the effective slope lim-
itation will be divided by the filter ratio. A value of 4095 will effectively disable slope l i m -
itation.
8.2.54
Afzup_Filter
Reg
Name
105
AFZUP_Filter
Description: The final filtering of new samples on the analogue inputs can be selected using this regis-
ter in combination with the read and write 'command' registers 100 and 101. The final
filtered value results from taking Filter/64 of the new sample plus (64-Filter)/64 of the old
value and storing the result in registers 81-88. A value of 64 effectively disables this
filtering, so the new sample simply replaces the old value.
8.2.55
FilterStatus
Reg
Name
106
FilterStatus
Description: This register contains status bits for the analogue input filters. The lowest eight bits hold
confidence errors for each of the eight inputs, while the highest eight bits hold the status
of their slope errors.
The filter status is updated each second. The confidence error bit will be set if more than
half of the samples within the last second fell outside either of the confidence limits.
The slope errors will be set if more than half of the samples within the last second were
slope limited.
208
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
32bit
R/W
1-4095
Size
Access
Range
32bit
R/W
2-4095
Size
Access
Range
32bit
R/W
1-64
Size
Access
Range
32bit
R
0-65535
Default
Unit
4095
1.221 mV
Default
Unit
4095
1.221 mV
Default
Unit
th
64
of new
64
sample
Default
Unit
0
MacTalk name
Confidence Max
MacTalk name
Max Slope
MacTalk name
Filter (on the Filter
setup screen)
MacTalk name
N/A (shown
graphically)

Hide quick links:

Advertisement

Table of Contents
loading