3.5

Specifications and Certifications

3.5.1
General specifications
Attribute
Standards
Safety category
Power supply (user I/O)
STO A
STO B
STO input ON voltage, min
STO input OFF voltage, max
STO input absolute max rating
Conductor type
Conductor size
Strip length
3.5.2
Environmental specifications
The installation must comply with all environmental, pollution degree, and drive enclo-
sure rating specifications required for the operating environment.
Category
Ambient temperature
Storage temperature
Relative humidity
Shock
Vibration
Surrounding environment
EMC
ATTENTION:
Failure to maintain the specified ambient temperature can result in a failure of the safety
function.
3.5.3
Certifications
Certification
TÜV
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Value
EN 60204-1, IEC 61508, EN 61800-3, EN 61800-5-1,
EN 61800-5-2, EN 62061, EN ISO 13849-1
Cat. 3 and PL e per EN ISO 13849-1;
SIL CL3 per IEC 61508 and IEC 62061
24V DC ±10%, 0.8...1.1 x rated voltage PELV or SELV
24 V DC, max. 10 mA
24 V DC, max. 10 mA
5 V
2 V
60 V
Multi-conductor shielded cable
24 AWG
10 mm
Specification
0...40 °C
-40...70 °C
5..93 % non-condensing
15 g, 30ms. (EN/IEC 60068-2-27)
5 - 25 Hz: ±1.6mm,
25 - 500Hz: 4 g, 1.0 oct./min.
(EN/IEC 60068-2-6)
The ingress protection (IPxx) depends on the specific motor type
number. Please see
Emission
IEC61800-3 (Category 2)
Noise immunity
IEC61000-6-2
Value
Certified by TÜV NORD for Functional Safety: 
up to SIL CL3, according to IEC 61800‐5‐2, IEC 61508, and EN 62061; 
up to Performance Level PLe and Category 3, according to EN ISO 
13849‐1; 
when used as described in this User Manual.
Ordering
information, page 353
Option