JVL MIS17 Series User Manual page 227

Integrated step motors, including step motor controller smc66, smc85
Table of Contents

Advertisement

8.2
8.2.106
TICKS
Reg
Name
202
TICKS
Description: Increments at a fixed rate of 1 count per millisecond. Starts at zero when CVI has
been applied.
8.2.107
CUR_SCALE_MAX
Reg
Name
212
CUR_SCALE_MAX
Description: Closed loop: Max running current in closed loop with "Current control" enabled. 2047
= 100 % of RUN_CURRENT.
8.2.108
CUR_SCALE_MIN
Reg
Name
213
CUR_SCALE_MIN
Description: Closed loop: Minimum running current in closed loop with "Current control" enabled.
2047 = 100 % of RUN_CURRENT. See also
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Internal registers
Size
Access
Range
32bit
R/W
0 - (2
Size
Access
Range
32bit
R/W
0 - 2047
Size
Access
Range
32bit
R
0 - 2047
Default
Unit
32
0
ms
-1)
Default
Unit
2047
Counts
Default
Unit
1
Counts
Special
settings, page 106.
MacTalk name
N/A
MacTalk name
N/A
MacTalk name
N/A
227

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents