5.10
5.10.2
Setup without MacTalk
If MacTalk is not used for setting up parameters and registers related to the under voltage
feature it must be done as follows.
The motor contains a number of registers which can be accessed from various protocols
depending at which options the motor has.
Protocols available are for example Ethernet (EthernetIP, PROFINET etc.) and CAN-
open, Modbus or the MacTalk protocol.
Each field in MacTalk described earlier in this chapter is accessing a register in the motor.
The registers that are relevant for the under voltage feature are:
R98
R124
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Under voltage Handling
MIN_BUSVOL
SetupBits
The voltage level that defines when an under voltage
situation is present at the P+ (main power).
See also: Min_Busvol, page 206
SetupBitsThe 3 bits that define what action should
be taken in case of an under voltage situation.
Bit 21: Under voltage -> Set error bit
Bit 22: Under voltage -> Stop controlled and go to
Bit 23: Under voltage -> Set velocity to 0
See also: Setup_Bits, page 213
If none of the above bits are set the motor will con-
tinue to run when the main power (P+) is back.
passive