Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-S500E
User Manuals: Mitsubishi Electric FR-S500E Inverter
Manuals and User Guides for Mitsubishi Electric FR-S500E Inverter. We have
1
Mitsubishi Electric FR-S500E Inverter manual available for free PDF download: Instruction Manual
Mitsubishi Electric FR-S500E Instruction Manual (194 pages)
Frequency Inverter
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 2.1 MB
Table of Contents
Table of Contents
6
Standard Connection Diagram
12
Standard Connection Diagram and Terminal Specifications
12
Explanation of Main Circuit Terminals
13
Main Circuit Terminals
16
Terminal Block Layout
16
Cables, Wiring Length, and Crimping Terminals
17
Wiring Instructions
18
Selection of Peripheral Devices
19
Leakage Current and Installation of Earth Leakage Circuit Breaker
20
Power-Off and Magnetic Contactor (MC)
24
Regarding the Installation of the Power Factor Improving Reactor
25
Regarding Noise and the Installation of a Noise Filter
26
Earthing Precautions
27
Power Supply Harmonics
28
Inverter-Driven 400V Class Motor
29
How to Use the Control Circuit Terminals
30
Terminal Block Layout
30
Wiring Instructions
30
Changing the Control Logic
31
Input Terminals
33
Run (Start) and Stop (STF, STR, STOP)
33
Connection of Frequency Setting Potentiometer and Output Frequency Meter (10, 2, 5, 4, AU)
36
External Frequency Selection (REX, RH, RM, RL)
37
Indicator Connection and Adjustment (AM)
39
Control Circuit Common Terminals (PC, 5, SE)
40
Signal Inputs by Contactless Switches
40
Current Input Selection "AU Signal": Pr. 60 to Pr. 63 Setting "4
41
How to Use the Input Signals (Assigned Terminals RL, RM, RH, STR)
41
Multi-Speed Setting (RL, RM, RH, REX Signals)
41
Pr. 60 to Pr. 63 Setting "0
41
Pr. 60 to Pr. 63 Setting "0, 1, 2
41
Remote Setting (RL, RM, RH Signals)
41
Second Function Selection (RT Signal): Pr. 60 to Pr. 63 Setting "3
41
Output Shut-Off (MRS Signal): Pr. 60 to Pr. 63 Setting "6
42
Start Self-Holding Selection (STOP Signal): Pr. 60 to Pr. 63 Setting "5
42
External Thermal Relay Input: Pr. 60 to Pr. 63 Setting "7
43
Jog Operation (JOG Signal): Pr. 60 to Pr. 63 Setting "9
43
Reset Signal: Pr. 60 to Pr. 63 Setting "10
44
PID Control Valid Terminal: Pr. 60 to Pr. 63 Setting "14
45
PU Operation/External Operation Switchover: Pr. 60 to Pr. 63 Setting "16
45
Connection of the Brake Unit (BU Type)
46
Connection to the Stand-Alone Option
46
Connection of the High Power Factor Converter (FR-HC)
47
Connection of the Power Regeneration Common Converter (FR-CV)
48
Connection of the Parameter Unit (FR-PU04)
49
Handling of the RS-485 Connector
49
Wiring of RS-485 Communication
50
Design Information
53
Functions
55
Function (Parameter) List
56
List of Parameters Classified by Purpose of Use
69
Explanation of Functions (Parameters)
71
Torque Boost (Pr. 0 , Pr. 46 )
71
Maximum and Minimum Frequency (Pr. 1 , Pr. 2 )
72
Base Frequency, Base Frequency Voltage (Pr.3 , Pr.19 , Pr.47 )
73
Acceleration/Deceleration Time (Pr. 7 , Pr. 8 , Pr. 20 , Pr. 44 , Pr. 45 )
75
Selection and Protection of a Motor (Pr. 9 , Pr. 71 , H7 )
77
DC Injection Brake (Pr. 10 , Pr. 11 , Pr. 12 )
79
Starting Frequency (Pr. 13 )
80
Load Pattern Selection (Pr. 14 )
81
Jog Operation (Pr.15 , Pr.16 )
82
RUN Key Rotation Direction Selection (Pr.17 )
82
Stall Prevention Function and Current Limit Function (Pr. 21 )
83
Stall Prevention (Pr. 22 , Pr. 23 , Pr. 28 )
85
Acceleration/Deceleration Pattern (Pr. 29 )
87
Extended Function Display Selection (Pr. 30 )
88
Frequency Jump (Pr. 31 to Pr. 36 )
88
Speed Display (Pr. 37 )
89
(Pr. 38 , Pr. 39 , C2 to C7 )
90
Biases and Gains of the Frequency Setting Voltage (Current)
90
Output Terminal Function Parameters
94
Start-Time Earth Fault Detection Selection (Pr. 40 )
94
Up-To-Frequency (Pr. 41 )
94
Output Frequency Detection (Pr. 42 , Pr. 43 )
95
Current Detection Function Parameters
96
Output Current Detection Functions (Pr. 48 , Pr. 49 )
96
Zero Current Detection (Pr. 50 , Pr. 51 )
97
Display Function Parameters
98
Monitor Display (Pr. 52 , Pr. 54 )
98
Setting Dial Function Selection (Pr. 53 )
99
Monitoring Reference (Pr. 55 , Pr. 56 )
100
Restart Operation Parameters
100
Restart Setting (Pr. 57 , Pr. 58 , H6 )
100
Additional Function Parameters
103
Remote Setting Function Selection (Pr. 59 )
103
Input Terminal Function Selection (Pr. 60 , Pr. 61 , Pr. 62 , Pr. 63 )
106
Terminal Function Selection Parameters
106
Output Terminal Function Selection (Pr. 64 , Pr. 65 )
108
Operation Selection Function Parameters
109
Retry Function (Pr. 66 , Pr. 67 , Pr. 68 , Pr. 69 )
109
PWM Carrier Frequency and Long Wiring Mode (Pr. 70 , Pr. 72 )
111
Voltage Input Selection (Pr. 73 )
112
Input Filter Time Constant (Pr. 74 )
113
Reset Selection/Pu Stop Selection (Pr. 75 )
113
Cooling Fan Operation Selection (Pr. 76 )
115
Parameter Write Disable Selection (Pr. 77 )
116
Operation Mode Selection (Pr. 79 )
117
Reverse Rotation Prevention Selection (Pr. 78 )
117
PID Control (Pr. 88 to Pr. 94 )
121
Auxiliary Parameters
128
Slip Compensation (Pr. 95 , Pr. 96 , Pr. 97 )
128
Automatic Torque Boost Selection (Pr. 98 )
129
Maintenance Output Function (H1, H2 )
130
Maintenance Parameters
130
Motor Primary Resistance (Pr. 99 )
130
Current Average Value Monitor Signal (H3, H4, H5)
131
Calibration Parameters
134
Meter (Frequency Meter) Calibration (C1 )
134
Alarm History Clear (ECL )
137
Clear Parameters
137
Parameter Clear (Clr )
137
Communication Parameters
138
Brake Parameters (FR-S520E-0.4K to 3.7K Only)
140
Communication Settings (N1 to N7 , N11 )
140
Operation and Speed Command Source (N8 , N9 )
155
Link Startup Mode Selection (N10 )
156
E2PROM Write Selection (N12 )
158
Caution
159
Parameter Unit (FR-PU04) Setting
159
PU Buzzer Control (N14 )
159
PU Display Language Selection (N13 )
159
PU Contrast Adjustment (N15 )
160
PU Main Display Screen Data Selection (N16 )
160
Disconnected PU Detection/Pu Setting Lock Selection (N17 )
161
Protective Functions
163
Errors (Alarms)
164
Error (Alarm) Definitions
165
Correspondence between Digital and Actual Characters
173
Resetting the Inverter
173
To Know the Operating Status at the Occurrence of Alarm (Only When FR-PU04 Is Used)
173
Motor Remains Stopped
174
Troubleshooting
174
Acceleration/Deceleration Is Not Smooth
175
Motor Current Is Large
175
Motor Rotates in Opposite Direction
175
Speed Does Not Increase
175
Speed Greatly Differs from the Setting
175
Speed Varies During Operation
175
Motor Produces Annoying Sound
176
Operation Mode Is Not Changed Properly
176
Operation Panel Display Is Not Operating
176
Parameter Write Cannot be Performed
176
Specifications
177
Ratings
178
Specification List
178
Common Specifications
180
Outline Drawings
182
Appendix
185
APPENDIX 1 Parameter Instruction Code List
186
Advertisement
Advertisement
Related Products
Mitsubishi Electric FR-S500 Series
Mitsubishi Electric FR-S520E-2.2K-NA
Mitsubishi Electric FR-S540E-0.4K-NA
Mitsubishi Electric FR-S540E-0.75K-NA
Mitsubishi Electric FR-S520SE Series
Mitsubishi Electric FR-S520SE-0.1K
Mitsubishi Electric FR-S510WE-0.2K
Mitsubishi Electric FR-S520E-0.75K
Mitsubishi Electric FR-S520E-1.5K-C
Mitsubishi Electric FR-S540E-2.2K
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL