Fixing Releasing Hp Sensor; Fixing Wrap Sensor - Canon imagerunner C5180 Service Manual

Hide thumbs Also See for imagerunner C5180:
Table of Contents

Advertisement

Chapter 11

11.5.13 Fixing Releasing HP Sensor

11.5.13.1 Preparation for Removing the
Fixing Release HP Sensor
1) Remove the fixing drive unit.(page 11-
32)Reference[Removing the Fixing Drive Unit]
2) Remove the fixing assembly.(page
33)Reference[Removing the Fixing Assembly]
3) Remove the fixing delivery lower unit.(page 11-
44)Reference[Removing the Fixing Delivery
Lower Unit]
11.5.13.2 Removing the Fixing Release
HP Sensor
1) Remove the fixing release HP sensor [5].
- 1 edge saddle [1]
- 1 connector [2]
- 1 screw [3]
- 1 fixing release HP sensor mounting plate [4]
[1]
[5]
F-11-83

11.5.14 Fixing Wrap Sensor

11.5.14.1 Preparation for Removing the
Fixing Wrap Sensor
1) Remove the fixing drive unit.(page 11-
32)Reference[Removing the Fixing Drive Unit]
2) Remove the fixing assembly.(page
33)Reference[Removing the Fixing Assembly]
3) Remove the fixing delivery lower unit.(page 11-
44)Reference[Removing the Fixing Delivery
Lower Unit]
11-50
11.5.14.2 Removing the Fixing Wrap
1) Remove the rod-shaped spring [1] connected to
11-
Be sure to fit the bend of the spring end and the
middle [A] of the spring on the hook found in the
fixing delivery lower unit.
2) Remove the sensor cover from the fixing delivery
[2]
[4]
[3]
3) Remove the fixing wrap sensor [1].
11-
Sensor
the fixing delivery lower unit. (Pull it out.)
Points to Note When Mounting the Spring
[1]
F-11-84
lower unit. (Move it away.)
- 4 screws, stepped [1]
[1]
F-11-85
- 1 connector [2]
[1]
[2]
F-11-86
[A]
[2]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner c4080Imagerunner c4580

Table of Contents