Canon imagerunner C5180 Service Manual page 637

Hide thumbs Also See for imagerunner C5180:
Table of Contents

Advertisement

Displayed
Detection timing
code
8001 When the entrance door switch is in
the open status even when all the
covers are closed
8002 When the delivery door switch is in
the open status even when all the
covers are closed
8003 When the front cover close
detection door switch is in the open
status even when all the covers are
closed
E602
Hard disk trouble
E604
Defective or insufficient image memory (SDRAM)
0000 When the amount of memory
required for the model has not been
recognized
0001 When the memory for the MEAP
applications is insufficient
0512 When the memory is defective or
insufficient (512 MB required)
0758 When the memory is defective or
insufficient (768 MB required)
1024 When the memory is defective or
insufficient (1024 MB required)
E609
Hard disk trouble
0008 When the HDD fails to reach the
prescribed temperature within the
prescribed period of time when it is
started up
0009 When the HDD fails to reach the
prescribed temperature when its
operation is restored from the sleep
mode
E610
Hard disk encryption key failure
0001 When there is no encryption board Install the encryption board.
0002 Defective or insufficient memory
0101 When the initialization of the area
of the memory where the key is
stored has failed
0102 When initialization of the encoding
area has failed
0201 Error in encoding area
0202 Error in encoding area
0301 When the preparation of the
encryption key has failed
0302 When an encryption key failure has
been detected
0303 When an encryption key failure has
been detected
0401 When an error has been detected in
the coding
0402 When an error has been detected in
the decoding
Remedial action
- Check the entrance door switch (MSW1), delivery door switch (MSW3)
and front cover close detection switch (MSW101).
- Replace the entrance door switch (MSW1), delivery door switch (MSW3)
and front cover close detection switch (MSW101).
Refer to "E602 details."
Increase the amount of the SDRAM memory.
Replace with an HDD which is guaranteed to operate at low temperatures.
Replace with an HDD which is guaranteed to operate at low temperatures.
Increase the amount of memory.
Turn the main power supply OFF and back ON. Replace the main controller
PCB.
Turn the main power supply OFF and back ON. Replace the encryption
board.
Turn the main power supply OFF and back ON. Replace the main controller
PCB.
The HDD is initialized by this error.
Turn the main power supply OFF and back ON. Replace the encryption
board.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner c4080Imagerunner c4580

Table of Contents